Designing railway vibrations isolation barriers using frequency-domain numerical modeling
1 Trofimuk Institute of Petroleum Geology and Geophysics of Siberian Branch of the Russian Academy of Sciences
2 Novosibirsk State University
3 Schmidt Institute of Physics of the Earth, Russian Academy of Sciences
4 Chinakal Institute of Mining of Siberian Branch of the Russian Academy of Sciences
Journal: Problems of Engineering Seismology
Tome: 53
Number: 2
Year: 2026
Pages: 79-101
UDK: 550.34.013.4
DOI: 10.21455/VIS2026.2-5
Show citation
Yablokov A.V., Serdyukov A.S., Dergach P.A. Designing railway vibrations isolation barriers using frequency-domain numerical modeling // . 2026. Т. 53. № 2. С. 79-101. DOI: 10.21455/VIS2026.2-5
@article{Yablokov Designing2026,
author = "Yablokov , A. V. and Serdyukov , A. S. and Dergach , P. A.",
title = "Designing railway vibrations isolation barriers using frequency-domain numerical modeling",
journal = "Problems of Engineering Seismology",
year = 2026,
volume = "53",
number = "2",
pages = "79-101",
doi = "10.21455/VIS2026.2-5",
language = "English"
}
Copy link
Copy BibTex
Keywords: vibration isolation, railway vibrations, numerical modeling, rock wool, XPS (extruded polystyrene), EPS (expanded polystyrene), polystyrene foam, combined barriers
Аnnotation: This paper presents the results of numerical modeling assessing the effectiveness of vibration barriers for protecting rail transport infrastructure elements, specifically tram tracks and subway tunnels, from vibrational impact. The study examines three types of structures: horizontal, vertical, and combined barriers made from rock wool, expanded polystyrene (EPS), and extruded polystyrene (XPS). The methodology is based on solving the elastodynamic equations in the frequency domain using a finite-difference scheme that accounts for the free surface and utilizes perfectly matched layers (PMLs). The results indicated that horizontal barriers are most effective when using XPS (up to 70% vibration reduction), but are susceptible to resonances at specific geometric dimensions. Vertical constructions exhibited a lower propensity for resonance phenomena, with an EPS vibration barrier demonstrating the potential for vibration reduction of up to 90%. Combined systems yielded the best performance, providing broadband protection (1–250 Hz) with an effectiveness of up to 97%. Key factors influencing effectiveness were identified as: material properties (durability, damping characteristics of rock wool, stiffness of XPS), geometry (width exceeding 0.6 m, depth exceeding 3 m), and frequency range. Practical recommendations include the use of horizontal barriers for high-frequency vibrations, vertical barriers for low-frequency vibrations, and combined structures for vibration protection across a broad frequency spectrum. The research opens prospects for the development of multilayered and non-standard geometric solutions, as well as for conducting field tests.